Xantrex GT3.0 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Zasilacze i falowniki Xantrex GT3.0. Xantrex GT3.0 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Solar Inverter

Xantrex Grid Tie Solar InverterOwner’s ManualGT3.0

Strona 2

Safetyviii 975-0131-01-01Regulatory ComplianceThe GT Inverter has complete on-board over-current, over-temperature and anti-islanding protection, and

Strona 3 - Owner’s Manual

SpecificationsA–6 975-0131-01-01AccessoriesGT Fan Kit (includes fan assembly and heat sink cover)Part number 864-0201Fan control Thermal, activates wh

Strona 4

975-0131-01-01 WA–1Warranty and Return InformationWarrantyWhat does this warranty cover? This Limited Warranty is provided by Xantrex Technology, Inc.

Strona 5 - About This Manual

Warranty and ReturnWA–2 975-0131-01-01What does this warranty not cover? This Limited Warranty does not cover normal wear and tear of the product or c

Strona 6 - Abbreviations and Acronyms

Warranty and Return975-0131-01-01 WA–3Return Material Authorization PolicyBefore returning a product directly to Xantrex you must obtain a Return Mate

Strona 7 - Related Information

Warranty and ReturnWA–4 975-0131-01-01Information About Your SystemAs soon as you open your Xantrex Grid Tie Solar Inverter package, record the follow

Strona 8

abbreviations and acronyms ivAC circuit breaker requirements 2–13AC grounding requirements 2–8AC output voltage ratings A–2AC utility voltage 4–2AC wi

Strona 9 - Important Safety Instructions

IndexIX–2 975-0131-01-01serial number WA–4knockout locations 2–16LEDs, See status LEDslightning protection 2–8long-distance grounding 2–8maintenance,

Strona 10 - FCC Information to the User

Index975-0131-01-01 IX–3do not illuminate 6–8red LED is on 6–8temperatureaffecting PV array performance 6–2range for locating Xantrex GT Inverter 2–4t

Strona 13 - Contents

Safety975-0131-01-01 ixVerification and Commissioning TestPurposeThis procedure is designed to verify correct operation of the Xantrex Grid Tie Solar

Strona 14

Xantrex Technology Inc.1 800 670 0707 Tel toll free NA1 360 925 5097 Tel direct1 800 994 7828 Fax toll free NA1 360 925 5143 Fax directcustomerservice

Strona 16

975-0131-01-01 xiImportant Safety InstructionsRegulatory Compliance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Strona 17 - 975-0131-01-01 xv

Contentsxii 975-0131-01-013Wiring the InverterAccessing the Wiring Terminals - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Strona 18

Contents975-0131-01-01 xiiiASpecificationsElectrical Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

Strona 20

975-0131-01-01 xvFigure 1-1 Basic System Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–2Figure 1-

Strona 22 - Grid Tie Inverter

975-0131-01-01 xviiTable 1-1 GT Inverter Models - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1–8Table

Strona 25 - Data Label

1IntroductionChapter 1, “Introduction”, contains information about the features and functions of the Xantrex Grid Tie Solar Inverter.The topics in thi

Strona 26 - Removable Components

Introduction1–2 975-0131-01-01About the Xantrex Grid Tie Solar InverterThe Xantrex Grid Tie Solar Inverter (GT Inverter) is designed to convert solar

Strona 27 - Front view

About the Xantrex Grid Tie Solar Inverter975-0131-01-01 1–3PV compatibility The GT Inverter is designed to take advantage of solar modules configured

Strona 28 - Model Configurations

Introduction1–4 975-0131-01-01Optional FeaturesGT Fan Kit (Xantrex part # 864-0201) includes:• Heat sink cover• Fan assembly.Figure 1-2Main Features o

Strona 29 - Installation

About the Xantrex Grid Tie Solar Inverter975-0131-01-01 1–5Safety and StandardsMeets standards and requirementsThe GT Inverter has complete on-board o

Strona 30 - Planning the Installation

Introduction1–6 975-0131-01-01Removable ComponentsThe wiring box is standard for all North American models of the GT Inverter. Some European models ar

Strona 31 - Installation Options Overview

Removable Components975-0131-01-01 1–7Optional Heat Sink Cover and FanIn areas where high ambient temperatures (>45°C/110°F) may be experienced (su

Strona 32 - WARNING: Burn hazard

Introduction1–8 975-0131-01-01Model ConfigurationsThe GT Inverter model number is in the format GTx.x-aa-bb-ccc, where:• x.x Output Power: 3.0 KW • aa

Strona 33 - PV Array Requirements

2InstallationChapter 2, “Installation”, provides information about planning for and installing the GT Inverter. It contains information to help you pl

Strona 34 - Voltage and MPPT Requirements

Xantrex Grid Tie Solar InverterOwner’s Manual

Strona 35 - 975-0131-01-01 2–7

Installation2–2 975-0131-01-01Installation OptionsThe GT Inverter may be installed as a single inverter for a single PV array of one or two PV strings

Strona 36 - Grounding Requirements

Planning the Installation975-0131-01-01 2–3Figure 2-1Installation Options OverviewUtility GridMain UtilityService PanelUtilityMeterLoadsPower routedto

Strona 37 - PV Array

Installation2–4 975-0131-01-01Inverter LocationInverter failure due to improper installation will void the inverter warranty. Consider the following w

Strona 38

Planning the Installation975-0131-01-01 2–5PV Array RequirementsGeneral RecommendationsIt is important that the PV array is installed correctly to the

Strona 39 - Routing the Wires

Installation2–6 975-0131-01-01Voltage and MPPT RequirementsMPPT operational windowEnsure that the PV array used in the system operates within the MPPT

Strona 40

Planning the Installation975-0131-01-01 2–7Guidelines for Matching PV Array Size to Xantrex Grid Tie Solar Inverter InputFor determining the number of

Strona 41 - Important:

Installation2–8 975-0131-01-01Grounding RequirementsAC Grounding North America The GT Inverter must be connected to a grounded, permanent wiring syste

Strona 42 - Equipment Needed

Planning the Installation975-0131-01-01 2–9Figure 2-2Basic Grounding OverviewGPrimary EarthGroundNeutral-to-GroundBondL1L2NEUTRALGROUNDMain UtilitySer

Strona 43 - Mounting the Inverter

Installation2–10 975-0131-01-01Figure 2-3Long Distance Grounding OverviewPrimaryEarthGroundArrayEarthGroundGND barAC/DC DisconnectSwitchNeutral-to-Gro

Strona 44 - Preparing to Mount the Unit

Planning the Installation975-0131-01-01 2–11Routing the WiresTypical configurationsDetermine all wire routes to and from the GT Inverter. Typical rout

Strona 45 - 975-0131-01-01 2–17

About XantrexXantrex Technology Inc. is a world-leading supplier of advanced power electronics and controls with products from 50 watt mobile units to

Strona 46 - Clearance Requirements

Installation2–12 975-0131-01-01Conduit holes/knockoutsPre-plan the wire and conduit runs. Knockouts for 1.9 cm (3/4 inch) or 2.5 cm (1 inch) conduit h

Strona 47 - WARNING: Explosion hazard

Preparing for the Installation975-0131-01-01 2–13Preparing for the InstallationEnsure your local utility is consulted for any requirements for connect

Strona 48 - Ground /

Installation2–14 975-0131-01-01AC/DC Disconnect SwitchThe wiring box includes a PV/Utility disconnect switch that switches both AC and DC at the same

Strona 49 - Ground / Floor Ground / Floor

Mounting the Inverter975-0131-01-01 2–15Mounting the InverterOverviewGeneral installation stepsThere are four main steps in the installation of the GT

Strona 50 - Mounting a Single Inverter

Installation2–16 975-0131-01-01In this chapter only the first step, mounting the inverter and installing accessories, is described.Mounting steps Inst

Strona 51 - Installing Accessories

Mounting the Inverter975-0131-01-01 2–17Installing the Mounting BracketThe mounting bracket for the GT Inverter allows the unit to be easily mounted a

Strona 52 - 2–24 975-0131-01-01

Installation2–18 975-0131-01-01Clearance RequirementsFor optimal and safe operation, ensure there is adequate clearance around the inverter. The minim

Strona 53 - Fan connectors

Mounting the Inverter975-0131-01-01 2–19Surfaces for MountingThe GT Inverter weighs approximately 20 kg (45 lbs). The supporting surface must be stron

Strona 54

Installation2–20 975-0131-01-01Mounting on Poles or RailsTo mount the unit using poles:1. Ensure that poles or rails are securely assembled in place.

Strona 55 - Wiring the Inverter

Mounting the Inverter975-0131-01-01 2–21Mounting on Wallboard, Siding or ConcreteTo mount the GT Inverter to wallboard, siding, or concrete:1. Locate

Strona 56 - Wiring box

975-0131-01-01 iiiAbout This ManualThe purpose of this Owner’s Manual is to provide explanations and procedures for installing, operating, maintaining

Strona 57 - Figure 3-2

Installation2–22 975-0131-01-01Mounting the Inverter on the BracketMounting a Single InverterTo mount the inverter on the mounting bracket:1. Place th

Strona 58 - Connecting the DC Wiring

Installing Accessories975-0131-01-01 2–23Mounting Multiple Inverters in ParallelAs shown in Figure 2-10, inverters can be mounted side by side on wall

Strona 59

Installation2–24 975-0131-01-01To attach the fan assembly to the inverter:1. Using a Phillips screwdriver, remove the four panhead screws and washers

Strona 60

Installing Accessories975-0131-01-01 2–25To connect the fan wires:1. Remove the wiring box cover by removing the two screws on the underside of the wi

Strona 61 - Connecting the AC Wiring

Installation2–26 975-0131-01-01Installing the Heat Sink CoverYou may find it easier to install the heat sink cover before mounting the inverter.If the

Strona 62 - 3–8 975-0131-01-01

3Wiring the InverterChapter 3, “Wiring the Inverter”, provides procedures for making DC and AC wiring connections, and grounding the GT Inverter and t

Strona 63 - Utility Grid

Wiring the Inverter3–2 975-0131-01-01Accessing the Wiring TerminalsYou must remove the GT Inverter wiring box cover to access the terminal blocks, gro

Strona 64 - 3–10 975-0131-01-01

Accessing the Wiring Terminals975-0131-01-01 3–3Figure 3-2AC and DC Terminal Block Location in the Wiring BoxDC Terminals for connecting PV arraysAC T

Strona 65 - Figure 3-6

Wiring the Inverter3–4 975-0131-01-01Connecting the DC WiringThe following procedure is illustrated in Figure 3-4. If there will be more than one PV s

Strona 66 - CAUTION: Equipment damage

Connecting the DC Wiring975-0131-01-01 3–5To wire the PV array to GT Inverter:1. Install DC conduit from the PV string(s) to the GT Inverter wiring bo

Strona 67 - 975-0131-01-01 3–13

About This Manualiv 975-0131-01-01Conventions UsedThe following conventions are used in this guide.Abbreviations and AcronymsWARNINGWarnings identify

Strona 68

Wiring the Inverter3–6 975-0131-01-01Figure 3-4DC Connections for Grounded PV ArrayImportant:Depending upon installation and local codes, fusing and/o

Strona 69

Connecting the AC Wiring975-0131-01-01 3–7Connecting the AC WiringThe GT Inverter can be connected to a single bi-directional meter, or to dual meters

Strona 70

Wiring the Inverter3–8 975-0131-01-01To wire the main utility service panel to the GT Inverter:1. Install conduit from the main utility service panel

Strona 71 - Communications cable

Connecting the AC Wiring975-0131-01-01 3–9Figure 3-5AC Connections from GT Inverter to Utility Service PanelL1L2NEUTRALGROUNDUtility GridUtilityMeterL

Strona 72

Wiring the Inverter3–10 975-0131-01-01Connecting Inverters in ParallelGT Inverters can be connected in a parallel configuration for larger PV array sy

Strona 73 - Starting the Inverter

Connecting Inverters in Parallel975-0131-01-01 3–11Figure 3-6Parallel GT Inverter DC and AC Wiring

Strona 74 - Startup Procedure

Wiring the Inverter3–12 975-0131-01-01Communications Wiring for Inverters in ParallelCommunications wiring between GT Inverters mounted in parallel al

Strona 75

Communications Wiring for Inverters in Parallel975-0131-01-01 3–13Terminators Male network terminators (Figure 3-8) are required at both ends of the n

Strona 76 - AC/DC Disconnect Switch

Wiring the Inverter3–14 975-0131-01-01Cabling RequirementsThe network uses Category 5 (CAT 5) cable, a standard cable available from any computer supp

Strona 77 - Monitoring the Inverter

Communications Wiring for Inverters in Parallel975-0131-01-01 3–15Purchasing Network ComponentsConsult with your system designer to determine what net

Strona 78 - Tap Xantrex logo for

About This Manual975-0131-01-01 vRelated InformationYou can find more information about Xantrex Technology Inc. as well as its products and services a

Strona 79 - Normal Operation Mode

Wiring the Inverter3–16 975-0131-01-01Connect the Communications Cable between Inverters in ParallelThe following procedure is illustrated in Figure 3

Strona 80

Communications Wiring for Inverters in Parallel975-0131-01-01 3–17Figure 3-11Communications Wiring for GT Inverters in ParallelPV Array #1GND barAC/DC

Strona 82 - Fault Mode

4Starting the InverterChapter 4, “Starting the Inverter”, contains information on starting up the Xantrex Grid Tie Solar Inverter and performing a Fun

Strona 83 - Fault Message Screens

Starting the Inverter4–2 975-0131-01-01Startup ProcedureStarting up the GT Inverter requires several steps. You will need to:1. Ensure the AC/DC Disco

Strona 84 - Special Screens

Replacing the Wiring Box Cover975-0131-01-01 4–3Replacing the Wiring Box CoverAfter performing the voltage checks, replace all covers that were remove

Strona 85 - Status Indicator Lights

Starting the Inverter4–4 975-0131-01-01Starting up the GT InverterTo start up the inverter:1. Switch the AC/DC Disconnect switch to the ON position (s

Strona 86 - Green LED

5Monitoring the InverterChapter 5, “Monitoring the Inverter”, contains information for understanding the LCD screens and the LED indicators.The topics

Strona 87 - Troubleshooting

Monitoring the Inverter5–2 975-0131-01-01Monitoring the Front Panel DisplayDuring startup During startup, the inverter’s front panel LCD (see Figure 5

Strona 88 - PV Array Factors

Front Panel Display Screens and What They Mean975-0131-01-01 5–3Front Panel Display Screens and What They MeanThe front panel display shows different

Strona 90

Monitoring the Inverter5–4 975-0131-01-01If there is sufficient energy from the PV array, this screen is displayed continuously while the system is op

Strona 91 - Protection Fuse

Front Panel Display Screens and What They Mean975-0131-01-01 5–5Additional messages for multiple unit systems onlyIn addition, to the normal system me

Strona 92

Monitoring the Inverter5–6 975-0131-01-01These message screens are common to all GT Inverter systems, no matter how many units are installed. If you c

Strona 93 - Front view Back view

Front Panel Display Screens and What They Mean975-0131-01-01 5–7Fault Mode causes These message screens only appear when there is a fault, and then fl

Strona 94

Monitoring the Inverter5–8 975-0131-01-01Additional Fault messages for all systemsAdditional message screens can be viewed in fault mode by tapping th

Strona 95

Status Indicator Lights975-0131-01-01 5–9Custom ScreensTwo custom screens are available. The inverter does not display them unless they are configured

Strona 96 - Electrical Specifications

Monitoring the Inverter5–10 975-0131-01-01RED Ground fault condition detected. Check for any fault messages on the display (see Table 5-8), and refer

Strona 97 - GT3.0 GRID TIE SOLAR INVERTER

6Maintenance and TroubleshootingChapter 6, “Maintenance and Troubleshooting”, contains information about how to provide general maintenance for the Xa

Strona 98 - TYPICAL EFFICIENCY [%]

Maintenance and Troubleshooting6–2 975-0131-01-01Factors Affecting GT Inverter PerformanceThis section describes several factors that will affect the

Strona 99 - Mechanical Specifications

Performing General Maintenance975-0131-01-01 6–3Other FactorsOther factors that contribute to system losses are:• Dust or dirt on the array • Fog or s

Strona 100 - Accessories

975-0131-01-01 viiImportant Safety InstructionsSAVE THESE INSTRUCTIONS—This manual contains important instructions that shall be followed during the i

Strona 101 - Warranty

Maintenance and Troubleshooting6–4 975-0131-01-01Replacing the Ground Fault Protection FuseThe ground fault protection fuse will blow when severe leak

Strona 102 - Disclaimer

Replacing Parts975-0131-01-01 6–5Replacing the InverterYou can swap out the inverter and replace it with another GT Inverter, leaving the existing wir

Strona 103 - Out of Warranty Service

Maintenance and Troubleshooting6–6 975-0131-01-01Recommended tools:• Insulated screwdriver• Wire nut for PV NEGATIVE (–) wire• 7 mm socket and small r

Strona 104 - Information About Your System

Replacing Parts975-0131-01-01 6–7To replace the inverter on the wiring box:1. If it has not already been removed, remove the front panel cover on the

Strona 105

Maintenance and Troubleshooting6–8 975-0131-01-01Identifying Error/Fault Conditions and SolutionsMost error or fault conditions will be identified by

Strona 106

ASpecificationsAppendix A, “Specifications”, contains information about the electrical and environmental specifications of the Xantrex Grid Tie Solar

Strona 107

SpecificationsA–2 975-0131-01-01Electrical SpecificationsInputOutputInput voltage, Maximum Power Point range 195 to 550 VdcAbsolute maximum array open

Strona 108

Electrical Specifications975-0131-01-01 A–3Adjustable Disconnect SettingsThe adjustable disconnect setting values vary depending on whether the invert

Strona 109

SpecificationsA–4 975-0131-01-01EfficiencyMaximum efficiency 94.6%Efficiency at 75% of nominal output power rating94.5%Euro efficiency 93.3%Nighttime

Strona 110 - Printed in China

Environmental Specifications975-0131-01-01 A–5Environmental SpecificationsUser DisplayDisplay AccuracyMechanical SpecificationsRated operating tempera

Komentarze do niniejszej Instrukcji